Elevator Mechanical Control Path inspection A. Task 27-31-61-210-801: Explanation where to look at:
(1) Open the Forward Access Door, 112A to get access to the elevator mechanical control path.
(2) Do a general visual inspection of the forward elevator mechanical control path.
Look at: Control columns connection tube and fwd control quadrants.
(3) Close the Forward Access Door, 112A,
(4) Remove the Tailcone Access Door, 318BR to get access to the elevator mechanical control path.
(5) Do a general visual inspection of the aft elevator mechanical control path.
Look at: Aft control quadrants, input torque tube, output torque tube, control pushrods.
(6) Install the Tailcone Access Door, 318BR.
There is a seperate inspection card for the ctrl cables and for the single-element-dual-load path components.